Remote Service Tool Software Manual
Page Contents
Introduction¶
Remote Service Tool displays and evaluates machine or vehicle data with a real-time connection to a target device, see About the Software for its main features.
About the Software¶
Remote Service Tool displays and evaluates machine or vehicle data of a target device. Download Remote Service Tool from the Download Center.
The main features are:
- Perform a real-time evaluation of diagnosis data while the target device is operating.
- Evaluate archived log files recorded by Remote Service Tool.
Note
The visual depiction of the machine or vehicle data is based on a DBS configuration file. Create this file according to the CAN bus specification of the target machine.
Note
The target device must be connected to a communication gateway that receives the machine data on the CAN bus and transfers it to Remote Service Tool.
Getting Started
Log In¶
Remote Service Tool supports logging in with both single sign-on (SSO) and a username and password.
Set a Default URL¶
Set a default URL to fetch the login information and use it as the default URL for logging into Remote Service Tool. Depending on the user settings, the SSO login, the native login with a username and password, or both are enabled.
- In Remote Service Tool, open Options > Preferences.
- Add the REST API URL, for example
https://dataportal.proemion.com/api/.

- Confirm with OK.
Log In Procedure¶
The Connections settings dialog window opens.
- Select Internet in the Communication path field.
The Internet connection settings section opens.

-
Depending on your settings, choose one of the following tabs to log in with a username and password or to use SSO login. In both cases, select Remember me to store the login information.
- Log in with username and password: enter your credentials and click Log In.
- Log in via SSO: change the REST API URL or add it here if not done yet, see Set a Default URL, then click Log In.
This opens the external login mask in the browser where you enter the SSO credentials. After a successful login, Remote Service Tool regains focus.
You can now use Find machines in this dialog, or any other feature within Remote Service Tool.
Log Out¶
To log out from both Remote Service Tool and SSO:
Create a Configuration Example¶
The following sections describe the first steps for the visual representation of a machine value, including useful information on configuring and establishing a connection with a telematics unit.
The example below describes the steps for displaying the engine speed, SPN 190 of PGN 61444 with priority 0x6 and source address 0x00 according to the J1939-71 standard.
The description assumes that a 29-bit CAN message with the CAN identifier 0x18F00400 is present on the connected CAN bus and transmits the current engine speed.
Note
If an Remote Service Tool configuration with the corresponding settings already exists, continue directly with Connect to a Device and Visualize Data.
- Make sure that the latest version of Remote Service Tool from the Download Center is installed on your PC.
- Start Remote Service Tool.
✓ The software starts with a blank project.
- Make sure that Project > Edit mode enabled (
Ctrl+E) is active in the menu.

- Right-click in the Main tab.
- Click Add element.
- Select Gauge from the available elements.

✓ The Gauge element is added to the main tab of your Remote Service Tool configuration.
- Right-click the new gauge element and click Configure….

✓ The configuration dialog for the gauge element opens.
- Click Source.

- Configure the gauge element according to the following table.

| # | Item | Setting |
|---|---|---|
| 1 | Active | Enabled. |
| 2 | Source name | Enter Engine Speed. |
| 3 | CAN channel | Select 0 for CAN1 (1 = CAN2). |
| 4 | Message type | Select 29 bit CAN message. |
| 5 | CAN identifier | Enter 18F00400 for PGN 61444 with priority 0x6 and source address 0x00. |
| 6 | Data type | Uint16 |
| 7 | Byte order | LSB first |
| 8 | First byte | 4 |
| 9 | Multiplier | 0,125 |
| 10 | Offset | 0 |
- Click Gauge within the Element configuration dialog.
-
Enter a Maximum value of
10000.
Figure 6: Gauge maximum value -
Click OK.
- Click the filter settings icon
. -
Select Auto filter (global).

Figure 7: Filter configuration Note
Enabling Auto filter (global) is typically the last step once the widget configuration is complete. Make sure it stays enabled once the Remote Service Tool configuration is finished, so the required filter masks are calculated.
-
Press
Ctrl+Eto disable Project > Edit mode enabled.✓ The gauge element and the required filter are configured.
Tip
If the correct CAN identifier is unknown, add a CAN Monitor element and create a CAN trace to determine the priority and source address for the PGN, see Record a CAN Trace with CAN Monitor.
-
Click Save (
Ctrl+S) to save the configuration as a.dbsfile for further tests.
Connect to a Device and Visualize Data¶
- Make sure that the latest version of Remote Service Tool from the Download Center is installed on your PC.
- Start Remote Service Tool.
✓ The software starts with a blank project.
- Click File > Open (
Ctrl+O). - Open the Remote Service Tool configuration file (
.dbs) with the settings described in Create a Configuration Example. - Click the connection settings icon
. - Select communication path Internet.
!!! note This example shows a connection to a CANlink® mobile device. Adapt this procedure to other communication gateways in the same way. When connecting to a local CAN-PC gateway, the Find machines steps don't apply.
- Enter the login credentials of your DataPlatform user.
!!! note Make sure the user account has the required Feature Switch, Permission Set, and machines assigned.
- Click Find machines.

- Select the corresponding machine.
-
Click OK.

Figure 2: Machine selection ✓ The connection is established and the CAN receive filter is written to the device.

Figure 3: Connecting Note
If you experience connection problems, see Connectivity Check.
-
Observe the pointer needle of the gauge element.
✓ The gauge element displays the current engine speed of the connected vehicle.

Figure 4: Engine speed
Customize the labels and appearance of the gauge element further, see Dashboard Elements.
Configuration
Use DBS Files¶
Note
Download and install the latest version of Remote Service Tool from the Download Center before using the features described in this chapter.
Use Remote Service Tool to create and open the DBS file. The DBS file contains:
- The graphic description of the display of machine and vehicle data.
- The description of machine and vehicle data available on the CAN bus of the target device.
Remote Service Tool creates the DBS file in XML format, then you can save the file to a computer hard drive.
The storage formats are:
- XML, an open format with a larger file size.
- A vendor-defined, compressed binary format with a smaller file size.
Remote Service Tool can only open one DBS file at a time. To copy project parts from one DBS file to another, open two instances of Remote Service Tool and copy the data you want using the Windows® clipboard.
Define the File Storage Format¶
- Click Options > Save files compressed in the menu bar to save the DBS file in a compressed format.
✓ A tick appears next to the menu option.

- Click Options > Save files compressed again to save the DBS file in an uncompressed format.
✓ The tick next to the menu option is removed.

✓ Remote Service Tool saves this setting and reapplies it the next time you start the program.
Create or Edit a Configuration File¶
To display CAN data, Remote Service Tool requires a configuration file with the file extension .dbs, which contains a complete specification of the CAN messages and their signals.
Different widgets can display the signals and states, see Dashboard Elements.
You can edit existing DBS files and create new DBS files.
State Indicator¶
The Machine Selection dialog indicates the different states of a device with colors:
- Green: hybrid devices with Online mode (logging and realtime modes) enabled, for example CANlink® mobile 3600, see CANlink mobile 3600 Online feature, or devices in logging/file transfer mode.
- Blue: devices in realtime mode, for example devices of the CANlink® mobile 3000 and CANlink® mobile 5000 series, and CANlink® mobile 3600 devices with a firmware version older than 2.0.
- Gray: devices that are offline.

Communication between Target Device and Remote Service Tool¶
Irrespective of the DBS file used to display the machine and/or vehicle data, assign a communication path in Remote Service Tool. This determines how the CAN bus data from the machines and/or vehicles transfers to Remote Service Tool through a communication gateway installed in the machine or connected to the machine's CAN bus.
Set the Communication Gateway¶
✓ This opens the following window:

Remote Service Tool supports the following communication gateways and their communication paths:
| Communication gateway | Communication path |
|---|---|
| CANlink® mobile | Internet |
| Bluetooth / USB | Serial connection to CANlink wireless (configured for Bluetooth connection) and CANview USB |
| WiFi / Ethernet | CANlink wireless (configured for WiFi connection), CANview Ethernet |
| Peak PCAN-USB | PCAN-USB CAN to PC gateway |
| CG150 CAN-USB | CAN-USB gateway device |
Depending on the chosen communication gateway, enter the parameters for the communication paths as described in the following sections.
Note
Click the Gateway status icon
to check the status of the connected gateway, including the firmware status and the configured CAN baud rate.
Connect an Internet Communication Gateway to a PC¶
Make sure that the respective CANlink® mobile communication gateway is online, and configure the communication path as an Internet interface.
| # | Item | Description |
|---|---|---|
| 1 | Communication path | Select Internet to establish a connection to a CANlink® mobile device. |
| 2 | User Name | Enter your DataPlatform user name. |
| 3 | Password | Enter your DataPlatform user password. |
| 4 | Find machines | Button to load the list of available machines for your DataPlatform account. Click the button and select the desired machine. |
| 5 | Selected machine | Shows the selected machine and its configured remote access password. After initially selecting the machine (4), enter the password GSMONLIN. This password is valid for all CANlink® mobile devices and is also included in the DODs (Device Object Dictionaries). |
| 6 | Machine selection | Click the required machine. Remote Service Tool marks the selected machine with a black triangle, see also State Indicator. |
| 7 | OK | Click OK to confirm the machine selection. |
| 8 | OK | Click OK to start connecting. |
Note
If you experience connection issues, see Connectivity Check.
Note
If there are issues with user login, permissions, or restricted access to machines, contact the designated DataPortal administrator of your organization to check the assigned features and permissions.
Connect a Bluetooth / USB Communication Gateway to a PC¶
Make sure that the serial connection between your PC and the required hardware is established.

| # | Item | Description |
|---|---|---|
| 1 | Communication path | Select Bluetooth / USB to establish a serial connection to a CANlink wireless or CANview USB device. |
| 2 | Serial Port | Select the virtual COM port of the connected CAN-PC gateway. |
| 3 | OK | Click OK to establish a serial connection to the selected gateway. |
Connect a WiFi / Ethernet Gateway to a PC¶
Make sure that the TCP connection between your PC and the required hardware is established.

| # | Item | Description |
|---|---|---|
| 1 | Communication path | Select WiFi / Ethernet to establish a TCP connection to a CANlink wireless or CANview Ethernet device. |
| 2 | IP | Enter the assigned IP address of the gateway within your network. |
| 3 | Port | Enter the configured port for the TCP configuration. |
| 4 | OK | Click OK to establish a TCP connection to the selected gateway. |
Connect a PCAN-USB Gateway to a PC¶
Make sure that the PCAN-USB gateway is connected to your PC.

| # | Item | Description |
|---|---|---|
| 1 | Communication path | Select Peak PCAN-USB to establish a serial connection to a PCAN-USB gateway. |
| 2 | Channel | Select the available PCAN-USB channel. If necessary, click the refresh icon. |
| 3 | Baudrate | Enter the baud rate of the connected CAN bus. |
| 4 | OK | Click OK to establish a serial connection to the selected gateway. |
Enable the Edit Mode¶
To modify an existing or new configuration file, enable the Edit mode.
- Click Project > Edit mode enabled in the menu bar to enable edit mode.

✓ In edit mode, you can customize the display interface using tabs and Dashboard elements.
| Depiction | Description |
|---|---|
![]() |
Edit mode is disabled. |
![]() |
Edit mode is enabled. You can move each element. |
- Click Project > Edit mode enabled again in the menu bar to quit edit mode.
Project Password (Dashboard Protection)¶
Remote Service Tool protects a dashboard against unauthorized or unintended modifications using a project password.
When a project password is set, editing the dashboard configuration is blocked unless you enter the correct password.
This feature separates configuration users (for example developers or service engineers) from standard users, who should only view data.
Enable a Password-Protected Dashboard¶
- Click Project > Edit mode enabled in the menu bar, see Enable the Edit Mode.
- Click Project > Project password in the menu bar.

- Enter a password and confirm it.

- Save the project using
Ctrl+S.
✓ Editing the dashboard is now protected by a project password. ✓ You can only modify the dashboard after entering the correct password.
Disable the Password Protection¶
- Click Project > Edit mode enabled in the menu bar.
- Click Project > Project password in the menu bar.
- Remove the password by setting it to blank.
- Confirm and save the project.
✓ You can now edit the dashboard without entering a password.
Behavior and Limitations¶
- The project password protects dashboard editing only.
- You can still view data and operate dashboard elements without a password.
- The password is project-based and stored in the DBS file.
- There is no user or role management. All users share the same project password.
- The protection applies to all tabs and dashboard elements within the project.
Additional Notes¶
- Remote Service Tool evaluates the project password when switching to Edit Mode. If a password is set, editing actions are blocked until you enter the correct password.
- Document and store the project password securely, since losing it prevents further modification of the dashboard configuration.
- When distributing DBS files, verify the password protection before delivery.
Typical Use Cases¶
- Delivery of validated dashboards to customers.
- Protection against accidental configuration changes.
- Use in remote diagnostics and after-sales environments.
Set the Resolution of the Software Interface¶
Select a resolution from the list, or customize the resolution of the software interface.
Select a Fixed Resolution¶
- Click Project > Fixed size in the menu bar.

- Click a resolution, for example 800x600.
✓ Remote Service Tool displays the software interface in the selected resolution.
Set a Customized Resolution¶
- Click Project > Fixed size in the menu bar.
- Click Add custom resolution.

- In the window that opens, enter the values for Width and Height.

- Click OK.
✓ Remote Service Tool displays the software interface in the specified resolution.
The Tab Display Concept¶
Structure the display elements by using several tabs.
If you haven't opened a DBS file, Remote Service Tool automatically shows an empty tab named Main.

Create a Tab¶
- In edit mode, right-click in the empty display area of the tab to open the context menu for the edit functions.

- Click Add tab to create a new tab.
✓ Remote Service Tool adds the new tab to the right of the existing tabs. You can change the order of the tabs on the display interface in edit mode using drag-and-drop.
A new tab is assigned a standard name with a consecutive number, for example Tab 1, Tab 2, and so on.
You can configure the name of the tab as well as further settings, see Configure a Tab.
Configure a Tab¶
- Right-click the tab name to open the context menu for the edit functions.
- Click Configure tab….

✓ The Tab configuration window opens.
General¶
- In the Tab title field, select the name you want from a list or enter a new name.
- Click Background color… to change the background color of the tab element.

- Click OK to confirm your change.
✓ Remote Service Tool saves the new text to a list. You can access all the saved names in all text entry fields through this list.
Message¶
In the CAN message settings area, configure a CAN message that is transmitted on the CAN bus when switching to the tab configured here during display.
Note
This CAN message can trigger certain actions in the machine. This requires corresponding programming on the machine side.

| # | Item | Description |
|---|---|---|
| 1 | Send CAN message on receiving focus | Enable this checkbox to transmit the configured CAN message on the CAN bus when this tab receives focus. |
| 2 | Message type | Define whether it's an 11-bit or a 29-bit message. |
| 3 | CAN identifier | Define the identifier of the CAN message as a hexadecimal value. |
| 4 | DLC | Define the number of data bytes to transmit (0...8). |
| 5 | Data bytes | Define the (bitwise) payload of the data bytes to send. |
| 6 | OK | Click OK to confirm the setup. |
Warning
Transmitting defective CAN messages can cause unwanted system reactions on the target device, and can lead to malfunctions or damage. Make sure the CAN messages to be transmitted contain correct commands.
Condition¶
In the Condition settings tab, define a CAN message that shows or hides a certain tab during runtime.

| # | Item | Description |
|---|---|---|
| 1 | Show tab only when the configured CAN message is received | Enable this checkbox to hide the tab until Remote Service Tool receives the defined CAN message. |
| 2 | CAN channel | Define the CAN channel (channel 0 = CAN1 interface at the CANlink® mobile). |
| 3 | Message type | Define whether it's an 11-bit or a 29-bit message. |
| 4 | CAN identifier | Define the identifier of the CAN message as a hexadecimal value. |
| 5 | Data bytes | Define the data bytes to receive (0...8). Assign hexadecimal values to them in the Data bytes fields. |
| 6 | OK | Click OK to confirm the setup. |
Delete a Tab¶
- Right-click the name of the tab.
- Click Delete tab.
✓ Remote Service Tool deletes the tab element and all the elements it contains.
Dashboard Elements
Dashboard Elements¶
Within the defined tabs, you can arrange and configure the evaluation and display elements described in this chapter.
Add a Dashboard Element to a Tab¶
- Right-click a tab name to open the context menu.
- Click Add element.

- Click a Dashboard element in the submenu.
- Move the Dashboard element onto the display interface.
- Use drag-and-drop to position the Dashboard element on the display interface.
- Click the edge of a Dashboard element and drag the edge out or in to change its size.
- Right-click a Dashboard element to open the context menu, then click Configure… to configure it. Alternatively, double-click its display area.
Available Dashboard Elements¶
| Element | Description |
|---|---|
| Label | Displays a text that you can edit and format. |
| Value | Displays a numerical value received through a CAN message. |
| Digital value | Shows a digital value received through a CAN message. |
| Bargraph | Shows up to 5 different values in the form of a bargraph. |
| Strip chart | Shows up to 5 different values in the form of a strip chart. |
| Send CAN message | Creates and configures a button to transmit a configurable CAN message to the remote CAN network. |
| Joystick | Displays up to 5 different values in the form of bar diagrams and/or freely configurable axes. |
| Gauge | Displays a value in the form of a tachograph/gauge. |
| Image | Displays graphics using configurable conditions. |
| Conditional text | Displays different texts using configurable conditions. |
| CAN Monitor | Displays received CAN messages. |
Label¶
The Label Dashboard element displays a text that you can edit and format. The Label element is part of every other Dashboard element.
Note
This chapter describes the configuration of the Label element as an example for all Dashboard elements.

- Right-click the Label element to open the context menu.

The context menu offers the following options, available for every Dashboard element:
| Context menu item | Description |
|---|---|
| Configure | Opens the configuration dialog for the Dashboard element. Alternatively, double-click directly on a Dashboard element, see General Tab. |
| Lock | Hides the Windows® frame of a Dashboard element and locks its position on the display interface. |
| Unlock | Shows the Windows® frame and unlocks the position on the display interface. |
| Undock | Undocks the Dashboard element from the display interface. The element then appears as an independent window on the desktop and can be freely positioned there. |
| Dock | Re-docks the freely positionable Dashboard element on the display interface. |
| Move to top | Places the Dashboard element in the foreground. |
| Move to bottom | Places the Dashboard element in the background. |
| Copy | Copies the selected Dashboard element. Alternatively, use the key combinations Ctrl+C and Ctrl+V. |
| Delete | Deletes the selected Dashboard element. |
For more on undocking, locking, and rearranging elements, see Display Types of a DBS File.
General Tab¶

| # | Item | Description |
|---|---|---|
| 1 | Window title | Select the name of the window you want from a list, or enter a new name. |
| 2 | Background color… | Changes the background color of the element. |
| 3 | Show border | Tick this box to show the element border. Remove the tick to hide the element border. |
| 4 | Show label | Tick this box to show the label text. Remove the tick to hide the label text. |
| 5 | Label text | Select the label text you want for the Dashboard element from a list, or enter a new name. |
| 6 | Label font | Shows the current font and font size of the label text. |
| 7 | […] | Opens the Font dialog. |
| 8 | Alignment | Choose the alignment of the label text in the Dashboard element. |
| 9 | Parent tab | Select the name of the tab to assign the selected Dashboard element to. If appropriate, Remote Service Tool transfers the Dashboard element to the selected tab. This option is only available when more than 1 tab is configured. |
| 10 | OK | Adopts a change. |
| 11 | Cancel | Cancels a change. |
Value¶
The Value Dashboard element displays a numerical value received through a CAN message.

General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Source Tab¶
In the Source tab, configure the CAN receive message for the value to show.
Some Dashboard elements have more than one source configuration area. In this case, there are tab sub-elements Source 1, and so on.
The following example describes a general configuration, common to all Dashboard elements with a Source tab.

| # | Item | Description |
|---|---|---|
| 1 | Active | Enable this checkbox to activate monitoring of the CAN message configured in this tab. Activation is necessary so Remote Service Tool transfers the values to display to the Dashboard element. |
| 2 | Source name | The name displayed for the data source, shown for information purposes only; the Value element doesn't evaluate it. Define the display name by entering it or selecting it from a list of available texts. In other elements, for example bargraphs and strip charts, this name is used for the legend. |
| 3 | CAN channel | Define the CAN interface: 0=CAN1, 1=CAN2, 2=CAN3. |
| 4 | Message type | Define the CAN message type. Choose between an 11-bit CAN message and a 29-bit CAN message. |
| 5 | CAN identifier | Enter the hexadecimal value of the CAN identifier of the CAN message to display. |
| 6 | Data type | Select the data type of the value to display within the CAN data. Available data types are Bit, Uint8, Int8, Uint16, Int16, Uint32, Int32, and Real32. |
| 7 | Byte order | Define the byte order (MSB or LSB first) used to calculate the value to display from the CAN data. |
| 8 | First byte | Select the data byte (1-8) from which the value to display starts within the CAN data. The data type determines the number of data bytes. |
| 9 | Multiplier | Enter a factor to multiply the value to display from the CAN data by before showing it. This value can contain digits after the decimal point. |
| 10 | Offset | Enter a constant value to add to the value to display from the CAN data before showing it. The value can contain digits after the decimal point, and can be positive or negative. |
| 11 | Decimals | Select the number of digits after the decimal point to show for the value. |
| 12 | Check for signal interval inconsistency | Activates the monitoring period within which Remote Service Tool must receive a CAN message. Remote Service Tool calculates the monitoring period automatically. |
Value Tab¶
In the Value tab, configure the unit and depiction of the value to display.

| # | Item | Description |
|---|---|---|
| 1 | Show unit | Enable this checkbox to show the specified unit for the signal value. |
| 2 | Unit text | Define the physical unit for the value to display by entering a unit or selecting it from a list of already available texts. |
| 3 | Value font | Shows the current font and font size for the value and the physical unit. |
| 4 | […] | Opens the Font dialog. |
Digital Value¶
The Digital value Dashboard element shows a digital value received through a CAN message.

General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Source Tab¶
The Source tab configuration is the same as for other Dashboard elements, see Source Tab.
Note
Not all parameters are available; some are disabled because this is bit information. The settings for Multiplier, Offset, and Decimals aren't available.
| Parameter | Value | Description |
|---|---|---|
| Data type | Bit | The data type of the value to display within the CAN data is fixed. |
| Byte order | MSB first, LSB first | This selection is disabled because this is bit information. |
| Bit | 0 to 7 | Position of the binary value to evaluate within the byte specified in First byte. |
LED Tab¶
In the LED tab, configure the LED depiction of the digital value to display.

| # | Item | Description |
|---|---|---|
| 1 | On color… | Determine the color the digital LED shows when it receives bit value 1. |
| 2 | Off color… | Determine the color the digital LED shows when it receives bit value 0. |
| 3 | Show on/off text | Tick the box to show an additional text on the LED. |
| 4 | On text | Define the text to display when Remote Service Tool receives bit value 1, by entering the text or selecting it from a list of already available texts. |
| 5 | Off text | Define the text to display when Remote Service Tool receives bit value 0, by entering the text or selecting it from a list of already available texts. |
| 6 | On text font | Shows the current font and font size for the On text. |
| 7 | Off text font | Shows the current font and font size for the Off text. |
| 8 | […] | Opens the Font dialog. |
Bargraph¶
The Bargraph Dashboard element shows up to 5 different values in the form of a bargraph.

General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Source Tab¶
The Source tab configuration is the same as for other Dashboard elements, see Source Tab.
Note
The Bargraph element supports up to 5 data sources. Configure the data sources in the tabs Source 1 to Source 5.

| # | Item | Description |
|---|---|---|
| 1 | Active | Tick the box to display the data source in the bargraph. |
| 2 | Source name | Enter a name for the data source, or select a name from the list. Remote Service Tool can display the name as a legend. |
| 3 | CAN channel | Define the CAN channel. |
| 4 | Color… | Select a color for the display of the data source. |
Graph Tab¶
In the Graph tab, configure the display options for the bargraph.

| # | Item | Description |
|---|---|---|
| 1 | Show legend | Tick this box to show the legend. Untick the box to hide the legend. |
| 2 | Show 3D effect | Tick this box to display the bargraph with a 3D effect. Untick the box to display the bargraph in 2D. |
| 3 | Y-axis autoscale | Tick this box to automatically scale the bargraph. Untick the box to configure the Y-axis by entering the values Y-axis min and Y-axis max. |
| 4 | Y-axis min | Enter the minimum value of the Y-axis. |
| 5 | Y-axis max | Enter the maximum value of the Y-axis. |
Strip Chart¶
The Strip chart Dashboard element shows up to 5 different values in the form of a strip chart.

General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Source Tab¶
The Source tab configuration is the same as for other Dashboard elements, see Source Tab.
Graph Tab¶
In the Graph tab, configure the display options for the strip chart, see also Graph Tab.

| # | Item | Description |
|---|---|---|
| 1 | X-axis scale | Enter the period in milliseconds to show on the X-axis. |
| 2 | X-axis divisions | Enter the division factor by which Remote Service Tool divides the period defined by X-axis scale. |
| 3 | Stairstep graph | Tick this box to display a stairstep graph. Untick the box to display a line graph. |
Send CAN Message¶
The Send CAN message Dashboard element creates and configures a button that transmits a configurable CAN message to the remote CAN network.
General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Message Tab¶
In the Message tab, configure the CAN message to send.
Warning
Transmitting defective CAN messages can cause unwanted system reactions on the target device, and can lead to malfunctions or damage. Make sure the CAN messages to be transmitted contain correct commands.
Note
In the example shown, a dynamic message is configured that sends when you press a button. Optionally, define a fixed and/or cyclical send message.

| # | Item | Description |
|---|---|---|
| 1 | Name | Define the button text by entering it or selecting it from a list of already available texts. |
| 2 | Font | Shows the current font and font size for the Name button text. |
| 3 | […] | Opens the Font dialog. |
| 4 | Message type | Select Dynamic or Fixed message. Selecting Dynamic message automatically enables a value check. |
| 5 | Message type | Select an 11-bit CAN message or a 29-bit CAN message. |
| 6 | CAN channel | Select the CAN interface of the gateway device (Ch0=CAN1, Ch1=CAN2, Ch2=CAN3). |
| 7 | CAN identifier | Enter the hexadecimal value of the CAN identifier of the CAN message to send. |
| 8 | DLC | Select the number of data bytes (0-8) in the data field of the CAN message to send. |
| 9 | Cycle time | Enter the cycle time for transmission of the CAN message. Clicking the configured button transmits the message cyclically when the cycle time is greater than zero; if the cycle time is zero, Remote Service Tool transmits the message exactly once. |
| 10 | Add, edit & delete icon | Use these buttons to add, edit, or remove a dynamic message. |
| 11 | Dynamic message overview | List of defined messages. |
| 12 | Parameter name | Defined name for the message. |
| 13 | Data type | Selected data type. |
| 14 | Endianness | Enable this checkbox for LSB first. Leave the checkbox disabled for MSB. |
| 15 | Start byte | Define the start byte for the data. |
Joystick¶
The Joystick Dashboard element displays up to 5 different values in the form of bar diagrams and/or freely configurable axes.

General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Source Tab¶
The Source tab configuration is the same as for other Dashboard elements, see Source Tab.
Note
The Joystick element supports up to 5 data sources. Configure the data sources in the tabs Source 1 to Source 5. The Color… button isn't supported for the data sources. Remote Service Tool uses Source name as the name for the axes, and only displays data sources that are Active.
Axes Tab¶
Define the position and behavior of up to 5 axes, as well as the depiction of the labels, in 6 sub-tabs. The Preview area shows a direct display of the changes you make.
Note
The preview shows the currently selected axis with a red frame.

| # | Item | Description |
|---|---|---|
| 1 | Orientation | Select between horizontal and vertical axis orientation. |
| 2 | Top | Define the distance between the axis and the top window edge in pixels. |
| 3 | Left | Define the distance between the axis and the left window edge in pixels. |
| 4 | Length | Define the length of the axis in pixels. |
| 5 | Width | Define the width of the axis in pixels. |
| 6 | Spacing | Define the spacing between two sections of an axis in pixels. |
| 7 | Value max | Define the maximum value of the axis for the +100% value of the data source. |
| 8 | Value mid | Define the middle value of the axis for the 0% value of the data source. This value also defines the line in the axis display that divides the two axis sections. |
| 9 | Value min | Define the minimum value of the axis for the -100% value of the data source. |
| 10 | Background color | Define the background color of the axis. |
| 11 | Color 1 | Define the color for the display of the deviation for the first axis section (0% to 100% of the axis). |
| 12 | Color 2 | Define the color for the display of the deviation for the second axis section (-100% to 0% of the axis). |
| 13 | Show axis labels | Tick this box to display the values Value max / Value mid / Value min. Untick the box to hide these values. |
| 14 | Label orientation | Define the position of the axis labels according to the orientation of the diagram. |
Legend Tab¶
Define the depiction of the legend. The Preview area shows a direct display of the changes you make.

| # | Item | Description |
|---|---|---|
| 1 | Show legend | Tick this box to display the legend. Untick the box to hide the legend. |
| 2 | Top | Define the distance between the legend and the top window edge in pixels. |
| 3 | Left | Define the distance between the legend and the left window edge in pixels. |
Gauge¶
The Gauge Dashboard element displays a value in the form of a tachograph/gauge.

General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Source Tab¶
The Source tab configuration is the same as for other Dashboard elements, see Source Tab.
Gauge Tab¶
The Gauge tab contains 4 further tabs for configuring the Dashboard element.
General Tab¶
Select the gauge predefined design and enter the minimum and maximum values.

| # | Item | Description |
|---|---|---|
| 1 | Sample designs | Select one of the available gauges as a basis for the further configuration. |
| 2 | Minimum value | Define the minimum value of the gauge scale. |
| 3 | Maximum value | Define the maximum value of the gauge scale. |
Design Tab¶
Define the gauge design details.

| # | Item | Description |
|---|---|---|
| 1 | Active needle damping with | Tick this box to enable needle damping, which prevents wobble during rapid value updating. This can lead to significant time lags that don't display high peaks. For connections through GSM and UMTS, disable this option. |
| 2 | Damping factor | Select a suitable damping factor. |
| 3 | Show gloss effect | Tick this box to enable a gloss effect on the gauge. Untick the box to disable it. |
| 4 | Show values | Tick this box to show the values on the dividing lines. Untick the box to hide them. |
| 5 | Value font | Shows the current font and font size for the scale values. |
| 6 | […] | Opens the Font dialog. |
| 7 | Gauge background color… | Define the background color of the gauge. |
| 8 | Needle style | Choose a visual style for the needle. |
| 9 | Gauge needle color… | Define the color of the gauge needle. |
| 10 | Show digit and unit | Enable or disable the display of the unit text and digital display. |
| 11 | Digit background color | Define the background color of the digital display. |
| 12 | Digit text color | Define the text color of the digital display. |
| 13 | Digit text format | Define the number of digits before and after the decimal point in the digital display in the format 0000.00 (here: four digits before the point with leading zeros, two digits after the point). You can't change the font. |
| 14 | Unit font | Shows the current font and font size for the unit text defined in Unit text. |
| 15 | […] | Opens the Font dialog. |
| 16 | Unit text | Define the unit text by entering a text or selecting one from a list of already available texts. |
Circle, Arc & Divisions Tab¶
Configure the start and end degree, the scale divisions, and whether the gauge appears as a full-circle or arc gauge.
Note
The 0° position for the degree count is horizontal, to the right of the center point. The degree count progresses clockwise in a positive direction.
For a full-circle gauge, the Circle start degree is 0° and the Circle end degree is 360°. For the Arc start degree and Arc end degree of a full-circle gauge, the end degree is usually set higher than 360°, and the start degree higher than 90°.
A scale can never be outside the background arc of the gauge. The degree settings of Circle settings restrict the degrees of Arc settings.

| # | Item | Description |
|---|---|---|
| 1 | Circle start degree | Define the start degree for the scale. |
| 2 | Circle end degree | Define the end degree for the scale. |
| 3 | Arc start degree | Define the start degree for the scale. |
| 4 | Arc end degree | Define the end degree for the scale. |
| 5 | Division count | Define the number of main divisions on the scale. |
| 6 | Division width | Define the width of the main division lines in pixels. |
| 7 | Division color | Define the color of the main division lines on the scale. |
| 8 | Subdivision count | Define the number of subdivisions on the scale. |
| 9 | Subdivision width | Define the width of the subdivision lines on the scale in pixels. |
| 10 | Subdivision color | Define the color of the subdivision lines on the scale. |
Sections Tab¶
Configure the start and end degree, the scale divisions, and whether the gauge appears as a full-circle or arc gauge.
Note
Overlapping sections produce new colors. Add the same section definitions multiple times to intensify colors.

| # | Item | Description |
|---|---|---|
| 1 | Sections list | Overview of defined sections. |
| 2 | Minimum value | Define the minimum value of a marked section. |
| 3 | Maximum value | Define the maximum value of a marked section. |
| 4 | Section color | Define the color of the section. |
| 5 | Delete section | Highlight a marked section in the list and click this button to delete it. |
| 6 | Add section | Click this button to add a marked section to the list. |
Image¶
The Image Dashboard element displays graphics using configurable conditions.

General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Source Tab¶
You can configure two data sources, see Source Tab.
Image Tab¶
Configure the display conditions for images.
Note
The top area lists all configured images with a brief summary of the settings for each. The order in the list determines which image Remote Service Tool actually shows: if one or more conditions are met, Remote Service Tool always shows the image furthest up the list.
Tip
Always load an image in the required size for an efficient configuration file.

Conditional Text¶
The Conditional text Dashboard element displays different texts using configurable conditions.

General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Source Tab¶
You can configure two data sources, see Source Tab.
Text Tab¶
Configure the display conditions for texts.
Note
The top area lists all configured texts with a brief summary of the relevant parameters. The order in the list determines which text Remote Service Tool actually shows: if one or more conditions are met, Remote Service Tool always shows the text furthest up the list.

CAN Monitor¶
The CAN Monitor Dashboard element displays received CAN messages.

| # | Item | Description |
|---|---|---|
| 1 | SRC | CAN channel. |
| 2 | ID | CAN ID. |
| 3 | TYPE | 11-/29-bit message. |
| 4 | DLC | Number of data bytes. |
| 5 | D1 … D8 | Message content. |
| 6 | TIME | Message timestamp. |
| 7 | COUNT | Number of messages with the same CAN ID (only shown when Relative mode is enabled in the Monitor tab). |
| 8 | Msg/s | Number of messages received per second. |
| 9 | Msg total | Total number of received messages. |
General Tab¶
The General tab is the same for every Dashboard element, see General Tab.
Monitor Tab¶
Configure the reception and display of the CAN messages for the CAN Monitor element.

Display Types of a DBS File¶
When you create a DBS file, you have two options for displaying the Dashboard elements. By default, newly created elements show on the surface of the Dashboard.
Right-click a Dashboard element to change its arrangement and depiction.

Undock/Dock¶
- Click Undock in the context menu.
✓ The element window undocks from the Dashboard surface and can be freely positioned on the desktop.

- Right-click the freely positionable Dashboard element.
- Click Dock in the context menu.
✓ The Dashboard element window docks on the Dashboard surface.
Lock/Unlock¶
- Click Lock in the context menu.
✓ Remote Service Tool locks the position and size of the element window (only when Edit mode is disabled), and hides the title bar and frame of the element window. The Lock function is especially useful for DBS files with many elements.

- Right-click the locked Dashboard element.
- Click Unlock in the context menu.
✓ Remote Service Tool displays the Dashboard element window with its own title bar and border.
Move to Top/Move to Bottom¶
Move Dashboard elements into the foreground or the background.
- Right-click a Dashboard element.
- Click Move to top in the context menu.
✓ The Dashboard element moves into the foreground.

- Right-click a Dashboard element.
- Click Move to bottom in the context menu.
✓ The Dashboard element moves into the background.

Copy and Paste of Dashboard Elements¶
Copy and paste Dashboard elements with all their settings.
- Click a Dashboard element to select it.
✓ The Dashboard element shows with a blue background.

!!! tip
To select several elements, press and hold Ctrl and click all the Dashboard elements you want to copy.
Press Ctrl+A to select all the Dashboard elements in the currently active tab.
- Press
Ctrl+Cto copy the selection. Alternatively, right-click a highlighted Dashboard element and click Copy in the context menu. - Press
Ctrl+Vto paste the copied Dashboard elements into another tab. Alternatively, right-click the name of the tab you want to paste the Dashboard elements into and click Paste in the context menu.
!!! note If you have opened a second instance of Remote Service Tool, you can also insert the copied Dashboard elements into a tab element in that second instance. When copying Dashboard elements to a separate instance of Remote Service Tool, the Merge Text Entries window opens, where you can merge the texts used with already existing texts, or enter new texts.
Merge Text Entries¶
The list contains all the texts transferred in a copying process. Remote Service Tool first searches for existing texts and tries to merge the new texts with existing texts.
Note
The Merge Text Entries window only appears when copying Dashboard elements to another instance of Remote Service Tool.

Filter Data in the Communication Gateway¶
Remote Service Tool supports various communication gateways for reading CAN bus information from the target device. Not every communication gateway has a transmission bandwidth that lets it transmit 100% of the CAN bus information to the software. Remote Service Tool writes the CAN filters of the application to the volatile memory (RAM) when it establishes the connection to the gateway device. These settings stay active until new filters overwrite them, or the device reboots.
Note
Not every CAN bus information affects the diagnosis application. You can create and save a DBS file with filter settings appropriate for the diagnosis application to the communication gateway used. Alternatively, you can manually configure the filter settings, for example if you use a different communication gateway.
Tip
For normal operation, enable Auto filter (global) as the optimal setting for the CAN receive filters. In rare cases, it may be necessary to configure a manual CAN receive filter instead, see the table below.

The filter settings have the following meanings:
| # | Option | Description |
|---|---|---|
| 1 | No changes | If you enable this filter setting, Remote Service Tool doesn't load any filter settings to the communication gateway at the start of a realtime data session. If available, Remote Service Tool uses the filter settings last used or configured in the communication gateway; if none are available, it reads off the data without filters. |
| 2 | Auto filter (global) | Enable this filter setting to optimize the filters for all tabs of the opened DBS file. The greater the number of tabs, the more CAN bus information Remote Service Tool reads in. If too much CAN bus information is transmitted, the bandwidth on the selected communication path may be exceeded. |
| 3 | Auto filter (per tab) | Enable this filter setting to optimize the filters for the currently selected tab of the open DBS file. If you switch to another tab, Remote Service Tool again optimizes the filters and transmits them to the communication gateway. The more elements under the active tab, the longer switching between tab elements takes. |
| 4 | Manual filter | Enable this filter setting to configure the filter manually using Options > Settings > Filter settings, see Configure a Manual CAN Receive Filter. |
Create and Edit Multi-Language Projects¶
Remote Service Tool saves the texts used in the application in a language table.
- Click Project > Edit mode enabled in the menu bar to enable edit mode.

- Click Project > Localization in the menu bar.
✓ This opens the language table in the Localization window. ✓ The language table lists all the texts used, managed in separate columns per language.

The Multiplex Solution¶
Remote Service Tool applications can also be developed as multiplex applications. This is useful when the transmission bandwidths for the CAN messages to display are limited, for example when using CANlink® mobile. In multiplex applications, CAN messages contain different information at different times. Various Dashboard elements in various tabs can display the transmitted information. During multiplexing, tabs switch automatically when Remote Service Tool receives the corresponding CAN messages.
- Click Project > Edit mode enabled in the menu bar to enable edit mode.
- Click Project > Multiplexing in the menu bar.

✓ This opens the Application settings window.

✓ Configure a Dashboard application as a multiplex application in the Application settings window, in the Multiplexing tab.
- Tick Multiplexing active to enable multiplexing.
- Configure the relevant CAN message as a multiplex message.
✓ When Remote Service Tool receives a multiplex message, it automatically switches to the tab whose value was received for the multiplex configuration. All CAN messages are depicted in the active tab.
To determine which tab shows when Remote Service Tool receives the multiplex message, use the additional value Multiplex configuration to configure the tab.
Note
The Multiplex configuration value is only visible and configurable once you configure the application as a multiplex application.

Warning
Remote Service Tool can only display CAN messages in a tab once the dashboard application has received the defined multiplex message, and rejects CAN messages until it receives the first multiplex message.
Extended Functionality
Create a Configuration with CAN Monitor¶
This procedure configures a CAN Monitor element and connects your communication gateway to record a CAN trace. Record a CAN Trace with CAN Monitor and Replay a CAN Trace build on this configuration to replay the CAN trace for verification of a specific configuration file, or for offline analysis of the recorded CAN trace with the CAN monitor.
- Make sure that the latest version of Remote Service Tool from the Download Center is installed on your PC.
- Start Remote Service Tool.
✓ The software starts with a blank project.
- Make sure that Project > Edit mode enabled (
Ctrl+E) is active in the menu.

- Right-click in the Main tab.
- Click Add element.
- Select CAN Monitor from the available elements.

✓ The CAN Monitor element is added to the main tab of your Remote Service Tool configuration.
- Right-click the new CAN Monitor element and click Configure….

✓ The configuration dialog for the CAN Monitor element opens.
- Click Monitor.
- Enable the radio button at Open up filter and show all messages.
-
Click OK.

Figure 4: Monitor configuration ✓ The CAN Monitor element is configured to receive all CAN messages present on the connected CAN bus.
Tip
To reduce the transmitted data volume and focus on specific messages only, configure the Custom filter settings.
- Select Auto filter (global).
- Click Save (
Ctrl+S) to save the configuration as a.dbsfile for further tests.
Record a CAN Trace with CAN Monitor¶
- Make sure that the latest version of Remote Service Tool from the Download Center is installed on your PC.
- Start Remote Service Tool.
✓ The software starts with a blank project.
- Click File > Open (
Ctrl+O). - Open the Remote Service Tool configuration file (
.dbs) with the settings described in Create a Configuration with CAN Monitor. - Click the connection settings icon
. - Select communication path Internet.
!!! note This example shows a connection to a CANlink® mobile device. Adapt this procedure to other communication gateways in the same way. When connecting to a local CAN-PC gateway, the Find machines steps don't apply.
- Enter the login credentials of your DataPlatform user.
- Click Find machines.

- Select the corresponding machine.
-
Click OK.

Figure 2: Machine selection ✓ The connection is established and the CAN receive filter is written to the device.

Figure 3: Connecting -
Observe the CAN Monitor element, and make sure it records the messages of interest.
✓ The CAN monitor displays the current CAN traffic of the connected vehicle.

Figure 4: CAN trace
Replay a CAN Trace¶
Replay a recorded CAN trace to verify a specific configuration file. You can also analyze the CAN trace with the CAN monitor element after stopping the session, once the machine is no longer online.
- Make sure that the latest version of Remote Service Tool from the Download Center is installed on your PC.
- Start Remote Service Tool.
✓ The software starts with a blank project.
- Click File > Open (
Ctrl+O). - Open the Remote Service Tool configuration file (
.dbs) that you want to verify.
!!! tip
Optionally, use a configuration file (.dbs) with the CAN Monitor element for the replay to analyze the CAN trace, see Create a Configuration with CAN Monitor.

✓ The replay of the CAN trace starts, and Remote Service Tool displays the values for the specific signals within the individual configuration elements.

Configure a Manual CAN Receive Filter¶
Remote Service Tool writes the CAN filters of the application to the volatile memory (RAM) when it establishes the connection to the CAN interface device. These settings stay active until new filters overwrite them, or the device reboots. For normal operation, enable Auto filter (global) as the optimal setting for the CAN receive filters. In rare applications, it may be necessary to configure Manual filters, as described in this chapter.

| # | Item | Description |
|---|---|---|
| 1 | Messages used by application | Shows an overview of the CAN message identifiers used in the active DBS file. Remote Service Tool shows CAN messages received by the filter channel of the communication gateway selected in the Gateway – CAN filter list in green. Highlight all filter channels in the Gateway – CAN filter list using Shift + click on the first and last entry to check whether all the CAN message identifiers are shown in green, meaning all messages can be processed. |
| 2 | Global filter | Tick Global filter (use one filter for all tabs) to use one filter for all tabs. This may require a larger transmission bandwidth than all communication paths support, but offers faster tab switches, since Remote Service Tool doesn't need to change the filter settings first. |
| 3 | CAN channel | Select 0 for CAN1, 1 for CAN2, and 2 for CAN3. |
| 4 | Default cycle time | The default time used when Downsample is enabled. |
| 5 | CAN filters list | Shows the configured filters. A maximum of 8 filters per CAN interface is available. |
| 6 | Active | Enable this checkbox to activate the configured filter. |
| 7 | Downsample | After a CAN message passes through the channel, the channel closes for the configured downsample time, then opens again with the same filter configuration. Leave this time set to 0 when the filter mask is open for more than one message. |
| 8 | Message type | Choose between an 11-bit or a 29-bit CAN message. |
| 9 | CAN identifier | Enter the required CAN identifier. If there's a cluster of CAN identifiers to receive with this filter, define the filter mask according to Filter Calculation. |
| 10 | Mask | Enter the filter mask 7FF (for 11-bit IDs) or 1FFFFFFF (for 29-bit IDs) to receive only a single CAN identifier. |
| 11 | Bitmask result | Shows information about the configured filter mask and the number of accepted messages. A binary 0 means the bit isn't evaluated (don't care). A binary 1 means the corresponding bit of a received CAN message must have the same value as the configured message ID. |
| 12 | Set | Click this button to apply the settings to the manual filter configuration. |
| 13 | List of messages accepted by filter | Shows all CAN message identifiers accepted by the filter highlighted in Gateway – CAN filter. |
| 14 | OK | Click this button once the filter configuration is complete. The window closes automatically, and Remote Service Tool sets the filter to Manual filter. |
| 15 | Cancel | Click this button to dismiss and abort the manual filter configuration. |
See Filter Message Example for a worked example of this dialog.
Check the Performance Monitor¶
The Performance Monitor provides an overview of the received CAN messages count and their distribution to the active widgets. Usually, Auto filter (global) calculates the masks for the CAN receive filter so that it only transmits the CAN messages relevant for the application.
- Click Options > Performance monitor….

- Check the number of received messages and their distribution to the active widgets.

You can also reset the counter in the performance monitor:

Filter Message Example¶
The following example shows how to define a CAN receive filter for PGN 61444 at the CAN1 interface of the gateway device. Assuming the priority and source address aren't known, the filter mask ignores the bits for priority and source address.
- Click the filter settings icon
. - Select Manual filter > Configure.
- Configure the manual filter as shown in the table below.

| # | Item | Setting |
|---|---|---|
| 1 | CAN channel | Select 0 for CAN1. |
| 2 | CAN filters list | Shows the configured filters. A maximum of 8 filters per CAN interface is available. |
| 3 | Active | Enable this checkbox to activate the configured filter. |
| 4 | Downsample | Leave this time set to 0 when the filter mask is open for more than one message. |
| 5 | Message type | Select 29 bit CAN message. |
| 6 | CAN identifier | Enter CAN identifier 0CF00400 for PGN 61444 with priority 0x3 and source address 0x0. |
| 7 | Mask | Enter filter mask 00FFFF00 to ignore the priority and source address for PGN 61444. If the complete CAN identifier is known, you can also enter 1FFFFFFF to receive only this single CAN identifier. |
| 8 | Bitmask result | Shows information about the configured filter mask and the number of accepted messages. |
- Click Set.
- Click OK.
- Save the configuration.
- Test the filter settings.
✓ Only messages allowed to pass the configured filter settings transmit to Remote Service Tool.

!!! note
In this example, the filter mask allows transmission of CAN identifiers 18F00400 and 0CF00400.
- Stop the session once Remote Service Tool displays the required messages.
Software Update¶
Remote Service Tool offers the option to search for software updates.

✓ This opens the Software update window.

✓ Remote Service Tool displays a message about the software version status.
- If a new version is available, follow the instructions to perform the update.
Note
The online software update of Remote Service Tool requires an outgoing FTP connection. Make sure the FTP port is open.
Connectivity Check¶
Tip
If you experience connectivity issues with Remote Service Tool, run the test below and contact your local IT administrators if the required connections aren't OK.
- Download
connectivity-check.exefrom the Connectivity Check web page.

- Run
connectivity-check.exeon the PC with Remote Service Tool installed.
✓ This runs a connectivity test to the Proemion default URLs and ports.
- Make sure that all connections are OK.

Service and Support¶
The latest versions of the drivers, software, firmware, and documentation are available at Document Library.
Do you need help or want to report a bug?
Visit Proemion for more information, or raise a ticket via Support.
Firmware Updates and Support¶
To ensure the best performance and security of your devices, we strongly recommend always installing the latest firmware provided by Proemion.
Please note:
We do not provide technical support for issues caused by outdated firmware.
Errors resulting from outdated firmware are considered non-qualified errors and are not covered by warranty or support.
Regular firmware updates are essential to maintaining the functionality of your devices.
If you need assistance with the update process, please contact our Service and Support.
For more information on the Firmware Update, check the device manual of your device at the Document Library.