Communication between Target Device and Remote Service Tool¶
Irrespective of the DBS file used to display the machine and/or vehicle data, assign a communication path in Remote Service Tool. This determines how the CAN bus data from the machines and/or vehicles transfers to Remote Service Tool through a communication gateway installed in the machine or connected to the machine's CAN bus.
Set the Communication Gateway¶
✓ This opens the following window:

Remote Service Tool supports the following communication gateways and their communication paths:
| Communication gateway | Communication path |
|---|---|
| CANlink® mobile | Internet |
| Bluetooth / USB | Serial connection to CANlink wireless (configured for Bluetooth connection) and CANview USB |
| WiFi / Ethernet | CANlink wireless (configured for WiFi connection), CANview Ethernet |
| Peak PCAN-USB | PCAN-USB CAN to PC gateway |
| CG150 CAN-USB | CAN-USB gateway device |
Depending on the chosen communication gateway, enter the parameters for the communication paths as described in the following sections.
Note
Click the Gateway status icon
to check the status of the connected gateway, including the firmware status and the configured CAN baud rate.
Connect an Internet Communication Gateway to a PC¶
Make sure that the respective CANlink® mobile communication gateway is online, and configure the communication path as an Internet interface.
| # | Item | Description |
|---|---|---|
| 1 | Communication path | Select Internet to establish a connection to a CANlink® mobile device. |
| 2 | User Name | Enter your DataPlatform user name. |
| 3 | Password | Enter your DataPlatform user password. |
| 4 | Find machines | Button to load the list of available machines for your DataPlatform account. Click the button and select the desired machine. |
| 5 | Selected machine | Shows the selected machine and its configured remote access password. After initially selecting the machine (4), enter the password GSMONLIN. This password is valid for all CANlink® mobile devices and is also included in the DODs (Device Object Dictionaries). |
| 6 | Machine selection | Click the required machine. Remote Service Tool marks the selected machine with a black triangle, see also State Indicator. |
| 7 | OK | Click OK to confirm the machine selection. |
| 8 | OK | Click OK to start connecting. |
Note
If you experience connection issues, see Connectivity Check.
Note
If there are issues with user login, permissions, or restricted access to machines, contact the designated DataPortal administrator of your organization to check the assigned features and permissions.
Connect a Bluetooth / USB Communication Gateway to a PC¶
Make sure that the serial connection between your PC and the required hardware is established.

| # | Item | Description |
|---|---|---|
| 1 | Communication path | Select Bluetooth / USB to establish a serial connection to a CANlink wireless or CANview USB device. |
| 2 | Serial Port | Select the virtual COM port of the connected CAN-PC gateway. |
| 3 | OK | Click OK to establish a serial connection to the selected gateway. |
Connect a WiFi / Ethernet Gateway to a PC¶
Make sure that the TCP connection between your PC and the required hardware is established.

| # | Item | Description |
|---|---|---|
| 1 | Communication path | Select WiFi / Ethernet to establish a TCP connection to a CANlink wireless or CANview Ethernet device. |
| 2 | IP | Enter the assigned IP address of the gateway within your network. |
| 3 | Port | Enter the configured port for the TCP configuration. |
| 4 | OK | Click OK to establish a TCP connection to the selected gateway. |
Connect a PCAN-USB Gateway to a PC¶
Make sure that the PCAN-USB gateway is connected to your PC.

| # | Item | Description |
|---|---|---|
| 1 | Communication path | Select Peak PCAN-USB to establish a serial connection to a PCAN-USB gateway. |
| 2 | Channel | Select the available PCAN-USB channel. If necessary, click the refresh icon. |
| 3 | Baudrate | Enter the baud rate of the connected CAN bus. |
| 4 | OK | Click OK to establish a serial connection to the selected gateway. |